Product Description

Detailed Product Description

Name:

Outdoor Split Core Current Transformer

Material:

Nickel-iron Permalloy

Application:

Power Energy Monitor

Color:

Orange Or Black

Burden:

2.5-10VA

Usage:

Outdoor Installation

Frequency:

40-400Hz

Theory:

Electromagnetic Induction

Diameter:

55mm

Ratio:

100-1500A/5A Or 1A

 

 

Theory

Split core current transformers are high accuracy class electrical devices used to isolate or transform voltage or current levels. The most common usage of current transformers is to operate instruments or metering from high voltage or high current circuits, safely isolating secondary control circuitry from the high voltages or currents. The primary winding of the transformer is connected to the high voltage or high current circuit, and the meter or relay is connected to the secondary circuit. Installation With electricity, suite for power monitor, energy loss etc.

Split core current transformers may also be used as an isolation instrument transformer so that secondary quantities may be used in phase shifting without affecting other primary connected devices.

 

Applications
Spit core current transformers are the current-sensing units of the power system. Split core current transformers are used at generating stations, electrical substations, and in industrial and commercial electric power distribution.
LZCK-55 waterproof outdoor split core current transformers are applicable for AC power system 35kV and measurement of current of power supply equipment below 10KV also can be used for microcomputer protection. This type of current transformer employs imported silicon steel which with high permeability as magnetic material, has the characteristics of Small magnetic circuit loss and can be split, its semicircular core and secondary windings employ high quality epoxy resin vacuum, casting in plastic-case(ABS or PC) which is flame retardance anti-moisture, stable performance, no maintenance.

 

Features
New magnetic material is taken to be the core of the current transformer, which has high magnetic permeability, low saturation magnetization and good stability. Therefore, the measuring accuracy is higher and the instrument security factor is lower. Since the high quality silicon processed by advanced technology is taken to be the core of the protection windings, which assured the accuracy limit factor is higher.
The semicircular ring core and secondary windings are vacuum poured by high quality epoxide resin in the fire retardant plastic casing, which has the characteristic of moisture proof, stable performance and dispensing with maintenance.Small size, light weight, small footprint, fixed in the ring network switchgear cable.The cable can cross the current transformer through its internal poles quickly and uniformly.
The Cast Resin Straight-Through Current Transformer can be divided several kinds according to the various current ratio, accuracy and rated loads. The specific parameters are showed in the corresponding to each model parameter tables.

 

 

PARAMETERS 

Technical parameters 

Standards

IEC60044-1; IEC 61869-2; NTC 2205; GB1208-2006; ANSI C57.13

Accuracy Class

0.5S, 0.5%, 1%, 3%

Range of primary rated current

100-1500A

Range of Rated load

≤10VA

Rated frequency

50/60Hz

Rated secondary current

5A or 1A

Rated short-time thermal current

40kA, 1S

Rated continuous thermal current

150%I1n

Secondary winding power frequency withstand voltage

3kV, 1min

Safety Factor Rating

(FS) <10

Output signal

1A, 5A, 333mV, 1V or 5V(customized)

Cable length

2.5m, 5m, 10m(customized)

Flame retardant ABS plastic shell inside, jaw waterproof apron.

Mechanical parameters 

Aperture (mm)

Φ55

Dimensions (W×D×H) (mm)

180×138×52

Weight (kg)

2

Working conditions 

Operating temperature

-35°C to +65°C, not exceeding +40°C

Storage temperature

-40°C to +70°C

Ingress Protection

IP65

Environment

outdoors or indoors

The Height of above sea level

0- 3000m

Conditions

No existence of severely begrimed, erosive and radioactive gas in the air. Continuous working under the rated current is allowed.

 

SELECTION GUIDE

 

Model

Primary rated current

Rated load

Aperture (mm)

Description (mm)

Weight (kg)

Material

Water-proof

LZCK-55

100-1500A

≤10VA

φ55

180×138×52

2

PC

IP67

LMCK185-10

300-3000A

≤25VA

φ185

350×283×55

4.5

PC

IP65

LZCK310-10

300-600A

≤10VA

φ50

φ50 x φ110 x 32

1

Resin

silicon case (option)

LZCK322-10

30-600A

≤10VA

φ50

φ50 x φ110 x 52

1.6

Resin

silicon case (option)

LZCK350-10

20-600A

≤25VA

φ50

φ50 x φ110 x 105

3.1

Resin

silicon case (option)

LZCG530-10

30-600A

≤20VA

φ45

φ45 x φ120 x 65

2.1

Resin

silicon case (option)
 

Price Terms︰EXWBeijing FOBBeijing CPT
Payment Terms︰TT/Western Union
Product Image






Related Products
AC Current Probe for cable fault tester
AC Current Probe for cable fault tester
US $ 150
Current Clamp Probe
Current Clamp Probe
US $ 150
Zero Sequence Current Transformer
Zero Sequence Current Transformer
US $ 120
Medium Voltage Split Core Current Transformer
Medium Voltage Split Core Current Transformer
US $ 120




Home  |  Product Catalog  |  News  |  Contact Us  |  Sitemap  |  Mobile Version

Powered by DIYTrade.com  Build your FREE website !
Find Best Price For China Products !